RECONSTRUCTION AND EXTENSION OF HOTEL „ŠUMADIJA“ IN ARANĐELOVAC
Client: “GP Best izgradnja” LLC, Novi Sad
Project: Reconstruction and extension of the “Šumadija” hotel in Aranđelovac
Location of works: Aranđelovac
Description and positions of works
Green roof above the congress hall of the new building
Roof layers:
-
TR trapezoidal sheet 154/280/0.75
-
Polyethylene vapor barrier Bauder DB 220
-
Stone wool ROCKWOOL ROOFROCK 50 Plus (d = 10 + 10 cm)
-
Root-resistant TPO membrane Bauder Thermoplan T15 (d = 1.5 mm)
Flat roof above the extended part of the existing building
Roof layers:
-
Bituminous vapor barrier Bauder EVA 40 (d = 4 mm)
-
Thermal insulation Bauder PIR FA 160 (d = 16 cm)
-
Bituminous waterproofing Bauder E-KV 4t (d = 4 mm) and Bauder E-KV 5 s (d = 5 mm)
Mansard roof of the extended part of the existing building
Roof layers:
-
Polyethylene vapor barrier Bauder DB 220
-
Stone wool ROCKWOOL ROOFROCK 50 Plus (d = 5 cm)
-
PVC membrane Thermofol U15 (d = 1.5 mm)
Waterproofing of the underground part of the new building
SikaProof waterproofing system:
-
Waterproofing of the reinforced concrete foundation slab and underground reinforced concrete walls using synthetic FPO membrane SikaProof A+12 (fully bonded system)
-
Construction joints in the foundation slab are additionally secured with PVC waterstops Sika Waterbar AF-24
-
Connections between the foundation slab and underground walls are additionally secured with swelling sealant Sikaswell S-2 and swelling profile Sikaswell A 2010
Material manufacturers used
Sika
Bauder